CONDENSING UNIT OPTION

Standard condensing units are air-cooled, and necessary componentry is pre-installed. Custom condensing unit enclosures are available separately. These are listed on page 9. Liquid and suction line runs of more than 30 ft. may require an upsized refrigerant receiver. Please call technical support for assistance. Water cooled units are also available by specifying WC-BCS-xx00 when ordering.

BCS-1000 Condensing Unit

Dimensions: 17.5"D x 13.5"W x 11.8"H

Weight: 42 lbs 

Liquid Line: 3/8"

Suction Line: 1/2"

Electrical: 120V

Cond. Unit MFS: 20A

Cond. Unit mca: 12.8 A

BTU capacity 25F suc, 90F amb: 4210

Refrigerant: 134A

BCS-2000 Condensing Unit

Dimensions: 24"D x 17.1"W x 16.7"H

Weight: 103 lbs 

Liquid Line: 3/8"

Suction Line: 3/4"

Electrical: 208/230V

Cond. Unit MFS: 25A

Cond. Unit mca: 16.9 A

BTU capacity 25F suc, 90F amb: 7980

Refrigerant: 134A

Air-cooled single evap

Air-cooled single evap

BCS-1500 Condensing Unit

Dimensions: 17.5"D x 13.9"W x 12.3"H

Weight: 73 lbs 

Liquid Line: 3/8"

Suction Line: 5/8"

Electrical: 120V

Cond. Unit MFS: 25A

Cond. Unit mca: 17.1 A

BTU capacity 25F suc, 90F amb: 6070

Refrigerant: 134A

BCS-3000 Condensing Unit

Dimensions: 24.1"D x 18.3"W x 16.6"H

Weight: 112 lbs 

Liquid Line: 3/8"

Suction Line: 7/8"

Electrical: 208/230V

Cond. Unit MFS: 40A

Cond. Unit mca: 23.9 A

BTU capacity 25F suc, 90F amb: 12600

Refrigerant: 134A

Water-cooled single evap

Water-cooled single evap

Installation Considerations

Air-cooled dual evap

Air-cooled dual evap

Water-cooled dual evap

Water-cooled dual evap

* 316 Stainless Steel construction on all evaporators.

* There are grommeted access holes for all electrical, refrigerant, and water connections.

* Crankcase heater included on condensing unit, to be field wired if necessary.

* Condensing unit also includes filter drier, sight glass, receiver, pressure controls, and fan cycling switch.

* Easy wiring – no high or low voltage between condensing unit and the evaporator.

* Supply 115 V to the evaporator, and 18-gauge control wire from the evaporator to the dual                                temperature/humidity indicator, the temperature sensor, and the humidity sensor.

* We supply prefabricated sheet metal transition adapters that run from the evaporator to 10” round on ducted    units (optional).

 

List of contractor supplied parts for install:

1. Double insulated refrigerant line set.

2. 1/4” copper water supply and saddle valve.

3. 1/4” condensate vinyl drain tube/tube clamps.

4. 120v circuit for indoor evaporator, and 120v/230v for outdoor condensing unit. Check local codes.

5. 18-2 stat wire; to be used to extend temperature sensor, humidity sensor cable, and keyboard.

6. Condensing unit pad.

7. Double gang box with a blank plate.